CUSTODIAL ROOM

CORPORATE OFFICES & DISTRIBUTION CENTERS

OVERVIEW

Maintaining facility cleanliness.


Functional, multi-use room to provide custodial staff with ample floor space & the right work tools.


Design Goals

  • Locate near the restroom and share the plumbing wall when possible; however, access should be separate from the restroom 

Serena Williams, PHK


Key Components

Area: 100 SF (9.6 SM)

Size:  10’ x 10’ (3.1m x 3.1m) 

Capacity: N/A


Download PDF and BIM files below

Download Drawings BIM Folder

REQUIRED SPECIFICATIONS

  • Clearances
    • Accessible shelves and placement of products should be reachable for a person using a wheelchair, with a reach range between 15”-48” (38cm-122cm) height
    • Highest and lowest shelves are not accessible so should be used for surplus materials, and/or materials should be organized vertically
  • Finishes

    Walls

    • Wall type 7: gypsum wall to deck
    • Use standard wall types or approved alternate that meets acoustic requirements.
    • Painted gypsum board with a rubber base (or equivalent). Full height fiberglass reinforced plastic (FRP) on walls around mop sink.

    Floors

    • Concrete or durable resilient floor for wet locations

    Ceiling 

    • Open to the structure
  • Doors
    • Type: Swinging with 3 hinges, solid core
    • Size: 36” x 80” (91cm x 203cm) or off the shelf size without customization
    • Handle: Metal lever-style
    • Lock and key
  • Casework and Plumbing
    • (x1) mop sink
  • Acoustics
    • Noise should be dampened between the room and adjacent spaces, but privacy isn’t required
    • Noise criteria (NC): 30-35 dBA
    • Sound transmission class (STC): 45-50 dBA
  • Equipment
    • (x1) Mop holder with 4 hangers min.
    • (x1) Chemical mixer
    • (x1) 6’ (1.8m) height, 18” (46cm) depth, 4-shelf rack
    • (x2) Hangers for backpack vacuums
  • Electrical

    Outlets

    • (x1) wall outlet min.

    Lighting

    • Range: 40-50 FC (430-538 LUX) at 30” (76.2cm) above the floor with suspended fixture
    • Controls: on/off with sensor
  • Wayfinding
    • See Wayfinding section
    • ID sign with the room type outside the door (‘Custodial Room’, ‘Utility Room’ or relevant local term)
  • Safety and Security
    • For Workplace Security standards, contact your local Design or PM team. EHS standards can be found in Resources